NAME
getaddrinfo —
resolve names to socket
addresses
SYNOPSIS
getaddrinfo |
[-cNnP] [-f
family] [-p
protocol] [-s
service[/protocol]]
[-t socktype]
[hostname] |
DESCRIPTION
The getaddrinfo utility resolves host and
service names to socket addresses with
getaddrinfo(3) and prints them to standard output in a
user-friendly format.
The output is a sequence of lines with space-separated fields:
socket-type address-family protocol
[af-specific data ...]For the “inet” and “inet6” address families, the af-specific data are the IP/IPv6 address and port number.
Depending on the settings in
nsswitch.conf(5), getaddrinfo might
query DNS for answers. However, it is not intended to be a general-purpose
DNS query utility. Use
drill(1) for that.
These options are available:
-c- Look up a canonical name as if with the
AI_CANONNAMEflag to getaddrinfo(3) and print it on the first line before the socket addresses. -ffamily- Specify an address family. Address families are named like the
AF_...constants for address family numbers in the ⟨sys/socket.h⟩ header file but without theAF_prefix and lowercase. For example, “inet” corresponds withAF_INET. -N- Treat the service as numeric and do not attempt service name resolution,
as if with the
AI_NUMERICSERVflag to getaddrinfo(3). -n- Treat the hostname as a numeric address and do not attempt name
resolution, as if with the
AI_NUMERICHOSTflag to getaddrinfo(3). -P- Return socket addresses intended for use with
bind(2), as if with the
AI_PASSIVEflag to getaddrinfo(3). By default, the socket addresses are intended for use with connect(2), sendto(2), or sendmsg(2). -pprotocol- Specify a protocol. Protocols are numeric or symbolic as listed in protocols(5).
-sservice[/protocol]- Specify a service to look up. Services are symbolic or numeric with an optional protocol suffix as listed in services(5). If a service is not specified, a hostname is required.
-tsocktype- Specify a socket type. Socket types are named like the
SOCK_...constants for socket type numbers in the ⟨sys/socket.h⟩ header file but without theSOCK_prefix and lowercase. For example, “dgram” corresponds withSOCK_DGRAM.
EXIT STATUS
The getaddrinfo utility exits 0 on
success, and >0 if an error occurs.
EXAMPLES
Look up “www.NetBSD.org”:
$ getaddrinfo www.NetBSD.org dgram inet6 udp 2001:4f8:3:7:2e0:81ff:fe52:9ab6 0 dgram inet udp 149.20.53.67 0 stream inet6 tcp 2001:4f8:3:7:2e0:81ff:fe52:9ab6 0 stream inet tcp 149.20.53.67 0
The port number here is zero because no service was specified.
Look up “morden.NetBSD.org” for stream sockets on port 80, and show the canonical name:
$ getaddrinfo -c -t stream -s 80 morden.NetBSD.org canonname ftp.NetBSD.org stream inet6 tcp 2001:470:1f05:3d::21 80 stream inet tcp 199.233.217.249 80
SEE ALSO
drill(1), getent(1), getaddrinfo(3), getnameinfo(3), resolver(3), hosts(5), nsswitch.conf(5), protocols(5), resolv.conf(5), services(5), ip6addrctl(8)
HISTORY
The getaddrinfo command first appeared in
NetBSD 7.0.